Understand the Basics of Centrifugal Pump Parameters
主页 > Technical support >   Text

    Centrifugal pumps are the most com-mon type of kinetic pump,and are used most often in applications with moderate-to-high flow and low head.As the workhorse of the chemical process industries(CPI), centrifugals are almost always more econom-ical to own,operate and maintain than other types of pumps.
        
                

    
                

    Parameters needed in specifying
        

    
                

    The process engineer is normally responsible for specifying the process requirements of the pump,includ-ing the conditions and physical properties of the liquid,and,most importantly,the flowrate,pressure,density and viscosity. The flowrate determines the capacity of the pump,and the head depends on the density and vis-cosity of the liquid. 
    
    In general,the required flowrate is determined by the material and energy balances. Design margins,typically between 0–25%,are added to the material-balance flowrate to account for unexpected variations in proper-ties or conditions,or to ensure that the overall plant meets its performance criteria. Also,minimum flow protection is often added as continuous circulation. Occa-sionally,the required flowrate (including design mar-gins) may fall in the low range of that for centrifugal pumps. In such cases,a minimum-size pump rated for continuous service is specified,and the extra pump capacity is typically consumed by circulation from the discharge to the source.
    

    During specification,the maximum pressure a pump will develop during any aspect of operation,including start up,shutdown and upset conditions is determined. The shut off pressure is the maximum pressure a pump will develop under zero-flow conditions,which reflects a fully blocked outlet. Variables to consider when deter-mining the design pressure include:     

    • maximum pressure of the source (e.g.,relieving pressure of a vessel)

    • maximum head developed by the pump (i.e.,shut-off head)

    • maximum static head of the fluid in the pump’s suction line

    • maximum pump operating speed (for variable-speed drives)

    • possibility of operator intervention during an upset.

    
    The head h is the most commonly used measurement of the energy at any point of the system,or of the system as a whole. It is defined as:

    

                             h=v2/2+ 2.31P/S+ z

    where v = the velocity of the fluid (ft/s); g = acceleration of gravity (32.2 ft/s2); P = pressure (psia); Sg= specifi cgravity; and z= elevation above (+) or below (–) the pump (ft).
    

    The energy that the pump imparts to the liquid,thetotal dynamic head,TDH ,takes into account differences in pressure,liquid elevation and velocity between the source and destination. In addition,TDH accounts for line(friction) losses and the pressure drop through the instrumen-tation and other items in the flow path of the liquid:

    
    
    

    
    

    
    

    

outlet louis vuitton
cheap nike free run 2 womens size 9
louis vuitton handbags china
louis vuitton outlet northern california
louis vuitton neverfull gm date code
louis vuitton neverfull gm date code
cheap nike free run 2 womens size 9
cheap Taj Gibson jerseys
louis vuitton handbags china
louis vuitton outlet northern california